John
Was unable to register to this Run due to work Issues , also my Cherokee is down . Planning to be Saturday for the day . Can I tag along to the Hard trails with you guys ?
Can take my bone stock Cherokee to the trail head & leave it there !!!
Dennis
Its all in the Cluster. Check Ignition Switch Output Fuse # 9 at Junction Block . If Voltage above 10 V , Check Cavity # 8 at Cluster for Battery Voltage , If OK'D , you probably need to replace Cluster . Before you replace Cluster Inspect wiring connector and put a little of Dialectric Grease...
You should have power at your Fan Relay at P.D.C on wires DB/WT & LG/RD coming from fuses # 15 & 18 ( P.D.C ) also...P.C.M provides ground to the relay at temperatures above normal ( 180 Degrees ) through wire DB/PK....
Bypass P.C.M ground circuit at relay in P.D.C and see if the fan turns...